Minimum Noise Negative Pressure Exhaurienda Evacuatione Fan Green Domus Usus Energy-salvis Ventilating Fans

High Efficiency 1460 Negative Air Pressure Ventilation Fan with afibreglasscompositae constructiones aptissima sunt ad exhauriendum aerium mordax gas et nebulas quae in aliquibus applicationibus praevalent.Gas mordax et caligo in ambitibus noxiis causam praematura gerunt in evacuatione instrumenti et damnum generale, quod rursus ad apparatum praemature deficientem ducit.UsusMarshineFRP VENTILATIO instrumenti in ambitibus corrosivis praebet solutionem tutam, quae diu operabitur.


Product Detail

Product Tags

1460-Model 57”(inch) Energy-saving Negative Air Pressure Ventilatione Fan

negans aeris pressura evacuatione fan (I)

negans aeris pressura evacuatione fan (II)

1. Quid est fibreglass negativa aeris pressio evacuatione ventilationis?

Fibreglass pressionis aeris negativa evacuatione ventilationis est novum genus armorum VENTILATIONIS exterioris formae factae materiae anti-corrosionis FRP.maxime adhibetur ut fossa ventilabrum et latus ventilabrum, qui efficaciter removere potest vaporem sordidum, ut NH3, H2S, et humidum aerem in fossa stercoris et domus feturae, et eliminare aestum, fumum, exhaurire gas, pulverem, etc. in late usu pecuaria, officina, etc.

Productum materia: Fibreglass pressura aeris negativa evacuatione ventilationis testarum 10mm crassitudo est.Valde erit stabilitas ac diuturnitas.Et Marshine exhaurit crassitudinem ventilabrorum limbi 18mm pro stabilitate et viribus institutionis comparabilis altioris.Fan impulsor frp SMC impulsor adoptat, inclinatio virium non minus quam 196 Mpa, utraque pars leves nimias, leves species, non rimas, hiatus, lappas et alios defectus, altiore effectu bonus est, ventilabrum rationabiles aerodynamicas, magnum volumen aeris gravis strepitus, efficacia, corrosio resistentia.
negans aeris pressura evacuatione fan (III)

2. Quae sunt fibreglass negativa pressura aeris evacuatione ventilabrum inclusa component?

FRP pressio negativa ventilabrum commutare potest aerem per pressuram negativam, quae finem consequi potest circulationis aeris, evacuationis et refrigerationis, unde etiam FRP pressura negativa ventilabrum appellatur.

1. Aspectus fit ex fluido, impervio, pluviali, magno aeris volubilis et humili strepitu.Producitur cum bonis materiis rudis, cum bono repugnantia impulsus, resistentia alta corrosio, superficies lenis et interior, et continua servitii vita plusquam XX annorum.
negans aeris pressura evacuatione fan (IV)
2. Testa facta est ex SMC corona, quae integratur, sine microsporis in superficie, munda et pulchra, facile ad mundum et nisi costo.Maxima proprietas eius est resistentia corrosionis et resistentiae acidorum et alcali.
negans aeris pressura evacuatione fan (V)
3. Ferrum ventilabrum ex SMC FRP effingitur et cum 6 laminis coadunatur.Inauguratus est, anti-corrosio, acidum et alcali resistentia, quies et stabilis operatio obtinet magnum volumen aeris, nulla deformatio, nulla fractura.
negans aeris pressura evacuatione fan (VI)
4. Lorem Lorem potestate et personas switch utendi non indiget.Principium eius est principium aeris.Lorem automatice aperiri et claudi potest ut pulvisproof, IMPERVIUS et elegantior aspectus efficiatur.Hoc Lorem leve est pondus et proprietates exhibet antioxidant.
negans aeris pressura evacuatione fan (VII)
5. Filum aeneum purum motor nationalis assumit vexillum mobile aes purum, velocitatem velocitatem;
magna potestas, potentia detrimentum tutelae fabrica, praesidium classis IP55, insulation genus F
negans aeris pressura evacuatione fan (VIII)
6. Ferens importata proprium habet velocitatis, sonum humilem, durabile, altum robur, non facile rubiginem, altissimum duritiem, non facile induendi.
negans aeris pressura evacuatione fan (IX)

3. Quae sunt magnitudo introductio pressurae negativae aeris ventilationi ventilationis?

Item No.

Dimensiones (mm)

Virtus (W)

Aeris flow

Voltage/Frequency

sonitus

Mobilitate gyrationis

Net Pondus

560#

560x560x440mm(22"x22"x17")

250W (3p)

10000 m³/h

5900CFM

380V/50Hz (solens) ;

≤45db

950rpm

35kg

680#

680x680x450mm(26"x26"x18")

250W (5p)

12000 m³/h

7200CFM

380V/50Hz (solens) ;

≤45db

820rpm

40kg

850#

850x850x480mm(33"x33"x19")

370W (8P)

17000m³/h

10000CFM

380V/50Hz (solens) ;

≤53db

620rpm

45kg

1060#

1060x1060x550mm(42"x42"x22")

550W (10P)

28000m³/h

16600CFM

380V/50Hz (solens) ;

≤55db

560rpm

50kg

1260#

1260x1260x560mm(50"x50"x22")

750W (10P)

37000m³/h

22000CFM

380V/50Hz (solens) ;

≤65db

520rpm

65kg

1460#

1460x1460x580mm(57"x57"x23")

1.1KW(10P)

45000m³/h 26500CFM

380V/50Hz (solens) ;

≤65db

450rpm

75kg

negans aeris pressura evacuatione fan (X)

4. Quid est placitum fibreglass negativa theoria pressurae ventilationis ventilationis?Magnam aeris tectis exhaustam facere differentiam pressionis aeris et vim extra aerem in cubiculum fluere.

1. Fibreglass negativa pressura aeris evacuatione ventilabrum habet characteres humilis investment sumptus, magnum volumen aeris, strepitus humilis, consummatio industriae humilis, operatio stabilis, longi muneris vita, et altae efficientiae.Flari vel extrahi potest, quae est electio refrigerationis et evacuationis in modernis officinis.Energy-saving negative pressionis ventilabrum fiet cinematographicae cinematographicae et refrigerationis instrumentorum.

2. Marshine Fibreglass Negativa Aeris Pressura Ventilatio Fan est typicam ventilationem et refrigerationem instrumenti, plerique artifices ventilationem pressionis negativae eligent quia non solum officinam et odorem praedium, altum calorem, fumum, etc. industria salutaris, environmental tutela et qualitas

3. Marshine fibreglass pressura aeris negativa evacuatione ventilabrum optimized secundum principium hydrodynamicorum.Aer exhauritus 46000-48000 metrorum cubicorum per hora est.Unum ventilabrum efficere potest ut officina 800 metrorum cubicorum semel per minutias aerem commutare possit.Virtus comparata solum est 0,75 kW, quae est industria salutaris et potentiae salutaris.

4. Fibreglass pressionis negativae aeris ventilationis ventilabrum adhiberi potest in omnibus fere locis refrigerationem vel evacuationem requirunt, cum longa opera vitae, operationis stabilis et soni minoris.
negans aeris pressura evacuatione fan (XI)

5. Quomodo fibreglass pressionis aeris negativa evacuatione ventilationis operatur ad firmam aeris evacuationem?

1. Evacuatione et refrigeratione: sicut sol in aedificiis, machinationibus et instrumentis, corporis humani et aliorum calorum fontibus, caliditas in locis evacuatione indigent, altior est quam foris.FRP pressio negativa ventilabrum adhibetur ut cito emittat gasi calidis tectis, ita ut caloris tectis externo temperie aequalis sit, ita ut temperamentum in officina non crescat.

2. Aer fluxus corporis humani calorem tollit.Aer fluxus sudoris evaporationem accelerat et calorem corporis humani absorbet, ita ut corpus humanum refrigerari sentiat, vel etiam vento naturali frigescat.FRP pressio negativa ventilabrum solum munus habet evacuationis et refrigerationis, et nullam functionem refrigerationis habet.Infrigidatio est sensus corporis humani.

3. Marshine Fiberglass negativa pressura aeris ventilationi ventilationis materia destinata ad gravissimas culturas productiones sustinendas, ambitus mordax gasi continet et componit ut: Ammonia acidum hydrochloricum, chlorinum, oxydorum Nitrogenium, sulphuris hydrogenium.Composita haec fibreglass fans non laedunt.

4. Marshine fibreglass pressionis aeris negativae evacuationis ventilabrum temptantur & librantur ad firmitatem obtinendam.Motor et lamina aequant ad liberandum consistentia, aerem dependentem cum pressione rating amplis statice fluentis.